ATS PANELS PRICE LIST

Bernini Design Romania is a European ATS panels manufacturer. If you purchase an old generator, our ATS panel will transform it into a modern standby system.

Automatic Transfer Switch For Generators

The key to success is the design: we keep it simple, essential and reliable. Our range covers the needs of standby generators from 5kVA up to 800kVA


CHOOSE YOUR PREFERRED LANGUAGE


Protect your business in case of a power outage

The ATS panel is conveniently tasked of switching your load to mains or generators. The power configuration and general arrangement are the same for all panels. The input-output lines for the engine connection and ancillary equipment depend on the type of controller fitted to the panel. An ATS panel continuously monitors the status of the utility power. You can set low and high limits for Voltage and Frequency. In other words, when the voltage and the frequency are within limits, the automatic transfer switch panel connects the load to the utility power. If the voltage drops below the lower limit (or rises above the high limit), the automatic transfer switch panel will disable the utility power circuit. This prevents, after a programmable delay, severe damage to your load. If the failure persists over the programmed time, the ATS panel will instruct the generator to start.


Using our ATS panels you can avoid purchasing brand-new expensive automatic generators. Purchase a low-cost second-hand generator. You will get a state-of-art backup power system.

With or without an electronic controller!

WITH OR WITHOUT ELECTRONIC CONTROLLER


CONTACTORS CHANGEOVER ATS PANELS PRICE

Our ATS panels feature two contactors with mechanical interlocks.  You will achieve a granular control monitoring and protection of your building's electrical system.

ATS panels online purchase

 

The contactors, usually four-pole, are coil-operated switches that close a circuit when the excitation coil is supplied with alternating 230V.

 ATS CONTROLLER TUTORIAL PAGE

KVA/Ac1 Price cm kg
15/32A 792€ 50x40x21 14
25/45A 877€ 60x40x25 16
40/63A 1086€ 70x50x25 22
60/100A 1403€ 70x50x25 28

MOTORIZED CHANGEOVER ATS PANEL PRICE

These ATS panels offer an internal manual override. This will allow you to activate manually the changeover switch. These ATS panels are recommended when involving high currents. You can connect generators without a built-in controller.MOTORIZED CHANGEOVER

The motorized ATS panel offers superior performance when it is too big currents. Starting from 80kVA we use the BeK3 controller that features CANbus and MODbus remote control monitoring options. You can connect RS485 drivers to get GSM and TCP/ip monitoring. You can purchase separately the MODEM and TCP/IP server

KVA/Ac1 Price cm kg
80/125A 1300€ 80x60x30 34
100/150A 1500€ 80x60x30 38
130/200A 1730€ 80x60x30 44
160/250A 1980€ 80x60x30 48

An ATS panel is one piece of electrical equipment capable of controlling a backup generator.


MAKE YOUR OWN ATS PANELS

YOU CAN MAKE YOUR OWN ATS PANEL FOR GENERATORS. LEARN HOW TO.

HOW TO MAKE ATS PANELS

Using the Be242 ATS controller and the Be242-RB universal interface board, you can make any ATS panel for generators from 15 up to 2000kVA generators. Purchase an old or a second-hand generator. Our controller will directly interface with it. See also this WEB TUTORIAL

HOW TO MAKE ATS PANELS FOR GENERATORS


BEFORE CONNECTING YOUR LOAD 

The ATS panel checks the quality of the generator voltage and frequency and will connect the generator circuit to your load when the parameters are within programmed limits. During a power outage, the automatic transfer switch panel monitors the utility power. When the utility power parameters return within the programmed settings, the automatic transfer switch panel will transfer the load to utility power. This will happen after a delay that will ensure that the utility power is in stable conditions. The engine will run offload after connecting your load to the utility power. Then, the engine will stop and the automatic transfer switch panel is ready for a new power outage.


 THE ATS PANEL WIRING DIAGRAM

In the following wiring diagram, you can see all the details about an ATS panel. The size of the wires, contactors, transfer switches or changeover, cabinet size, and terminal blocks, depend on power rating.

OPEN THE HD ATS PANEL WIRING DIAGRAM PDF

The wiring diagram is the same for all sizes. Download the following documents to find all the answers you are looking for.


WHAT KIND OF GENERATOR CAN YOU USE WITH OUR ATS PANELS?

Our ATS panels support all engines and generators. You can upgrade a second-hand generator by using our automatic transfer switch panel.

how to connect an old generator

The internal interface board of our automatic transfer switch panels features all relays that interface with all kinds of engines. In other words, you do not need any controller fitted with your generator. Our ATS panel will take care to control all functions. If you own an old generator, check the electric start and stop.


WHY DOES USING OUR ATS PANELS EXPONENTIALLY INCREASE THE LONG-TERM RELIABILITY OF STANDBY GENERATORS?

This is because of a big misunderstanding about overvoltages and flashes of lightning. The low-cost controllers on the market are erroneously placed on the frame of generators. This forces the user to connect the UTILITY power wires to the controller inside the generator. Despite all your efforts, you will never get protection from the electronic boards. The wires' parasitic capacitance cannot be eliminated.

NEVER DO LIKE THIS WITH AN ATS PANEL

It is a money-saving practice to connect the cables of the mains directly to the ATS controller.

WRONG ATS PANEL CONNECTION

This is an unsafe practice. Forget about it!

 CONNECT THE ATS PANEL IN THIS WAY

The overvoltages will never hit your generator.

SAFE WAY TO CONNECT AN ATS PANEL

The ATS controller will protect your generator from mains surges. You can optionally use your auto-start module, or use the normal input-output lines of the ATS controller.


HOW TO USE THE ATS PANEL?

Our ATS panels are based on the user-friendly ATS controller.  In this example, we describe the way to use the ATS controller.

Push the AUTO button. The ATS controller will automatically manage all tasks. The MANUAL button always overrides the automatic mode. The basic protections will always be active. This prevents dangerous situations offering a large flexibility of use. You can manually start and stop the engine and manually control the changeover switch.

THE LOAD IS CONNECTED TO THE MAINS

THE LOAD IS CONNECTED TO THE MAINS

THE LOAD IS CONNECTED TO THE GENERATOR

THE LOAD IS CONNECTED TO THE GENERATOR

AUTO MODE OF OPERATION

AUTO MODE OF OPERATION

The ATS controller must be programmed in the factory according to the panel size. To adapt the panel to your application you may need to program some settings. The programming is easy. Use the navigation buttons on the controller's front panel. You can download the following user's manual:

ATS CONTROLLER INSTALLATION MANUAL

This panel supports all kinds of engines. The internal interface board features all the relays you need to start and stop the engine. You can connect the automatic transfer switch panel to a generator fitted with any auto-start module.


ATS PANELS FEATURES

UTILITY POWER  OVER-UNDER VOLTAGE AND FREQUENCY MONITORING

GENERATOR OVER-UNDER VOLTAGE AND FREQUENCY MONITORING

OVERLOAD MONITORING

BATTERY MONITORING

INTERFACES WITH THE ENGINE

  INTERFACES CONTACTORS

INTERFACES TRANSFER SWITCHES

ADJUSTABLE OVERLOAD PROTECTION

OVER 70 ADJUSTABLE SETTINGS

USER-FRIENDLY INTERFACE

WIDE OPERATING TEMPERATURE RANGE


BERNINI DESIGN SRL

Zona Industriale

46035 Ostiglia

Italy

 VAT IT01453040204

bernini@bernini-design.com

+39 335 7077148

Scroll to Top